Phone: +48 91 485 86 59
Fax: +48 91 880 36 77
   updated: 2010-03-16
 
Not logged in - login/register help 
Search:
 
gsm news unlock software gsm forum
 INDEX
Search in description
 
 
 




 





 
 

  • e51
  • p1i
  • 6120 lcd display
  • n97
  • n95 lcd
  • l310
  • 6120 classic
  • 6233
  • 6234
  • rzep
  • T689
  • i900
  • n95
  • FBUS
  • z3x lg box
  • zasilacz
  • camera
  • nokia 6120 classic
  • tip
  • e72


  •  
     
     
    Housing Nokia 6210n - black ( original )
    as low as: 18.42EUR
    Housing Nokia 6210n - black ( original )
    Housing ( Front + Back ) Nokia 6610i - black ( original )
    as low as: 10.39EUR
    Housing ( Front + Back ) Nokia 6610i - black ( original )
    Housing ( Complete ) Nokia 5300 - black ( original )
    as low as: 20.58EUR
    Housing ( Complete ) Nokia 5300 - black ( original )
    Housing Nokia 6170 ( original )
    as low as: 5.15EUR
    Housing Nokia 6170 ( original )
    LCD frame Nokia 9500 - grey ( original )
    as low as: 34.17EUR
    LCD frame Nokia 9500 - grey ( original )
    Housing ( Front ) Nokia 6301 ( original )
    as low as: 12.56EUR
    Housing ( Front ) Nokia 6301 ( original )
    Housing ( Front + Back ) Nokia 7310 - green ( original )
    as low as: 12.25EUR
    Housing ( Front + Back ) Nokia 7310 - green ( original )
    Housing ( Front + Flap ) Nokia 6111 - black ( original )
    as low as: 10.39EUR
    Housing ( Front + Flap ) Nokia 6111 - black ( original )
    HOLSTER FORCELL - FASHION 50 - size L blue
    as low as: 2.87EUR
    HOLSTER FORCELL - FASHION 50 - size L blue
    HOLSTER FORCELL - FASHION 90 - size M ORANGE
    as low as: 2.28EUR
    HOLSTER FORCELL - FASHION 90 - size M ORANGE
    BATTERY SAM X450 / E100 750m / Ah Li - Ion BLUE STAR
    as low as: 3.73EUR
    BATTERY SAM X450 / E100 750m / Ah Li - Ion BLUE STAR
    BATTERY SAM X830 500m / Ah Li - Ion BLUE STAR - WHITE
    as low as: 3.90EUR
    BATTERY SAM X830 500m / Ah Li - Ion BLUE STAR - WHITE
    BATTERY LG KU990 700m / Ah Li - Ion BLUE STAR
    as low as: 3.62EUR
    BATTERY LG KU990 700m / Ah Li - Ion BLUE STAR
    CASE FORCELL - SLIM - SAM i900 OMNIA / iPHONE 3G / NOK E71 RED
    as low as: 2.00EUR
    CASE FORCELL - SLIM - SAM i900 OMNIA / iPHONE 3G / NOK E71 RED
    VERTICAL CASE - NOK 5800 RED
    as low as: 3.05EUR
    VERTICAL CASE - NOK 5800 RED
    HOLSTER FORCELL - FASHION 600 - size M light - blue
    as low as: 2.28EUR
    HOLSTER FORCELL - FASHION 600 - size M light - blue
     
     
    Currency: EUR USD
    Items in cart: 0 Total: 0 EUR
     
    New Page 1

    Test 01 info of serving cell 

    NET MONITOR
    TEST 01
    ++++++++++++++
     +abbb ccc ddd+
     + e ff g mmmm+
     + nnn     ppp+
     +    oooo    +
     ++++++++++++++
     
             a       H, if carrier numbers are scrolled when hopping is on.
                     Otherwise ' '.
             bbb     When mobile is on TCH: DCH carrier number in decimal.
                     If hopping is on, used channels are scrolled when display is
                     updated.
             ccc     rx level in dBm, minus sign not shown if <=-100
             ddd     tx power level. If transmitter is on, symbol * is shown in
                     front of the power level value.
             e       Time Slot, range is 0 - 7
             ff      Timing advance, range is 0 - 63
             g       rx quality (sub), range is 0 - 7
             mmmm    Radio Link Timeout value. If value is negative, 0 is shown.
                     Maximum value is 64. When mobile is NOT on TCH then xx is shown.
             nnn     value of the path loss criterium (C1). Range is -99 - 999.
             oooo    type of current channel
                         THR0 : TCH HR subchannel 0
                         THR1 : TCH HR subchannel 1
                         TFR  : TCH FR
                         TEFR : TCH EFR
                         F144 : TCH FR data channel, speed 14.4 kbps
                         F96  : TCH FR data channel, speed 9.6 kbps
                         F72  : TCH FR data channel, speed 7.2 kbps
                         F48  : TCH FR data channel, speed 4.8 kbps
                         F24  : TCH FR data channel, speed 2.4 kbps
                         H480 : TCH HR data channel, speed 4.8 kbps, subch 0
                         H481 : TCH HR data channel, speed 4.8 kbps, subch 1
                         H240 : TCH HR data channel, speed 2.4 kbps, subch 0
                         H241 : TCH HR data channel, speed 2.4 kbps, subch 1
                         FA   : TCH FR signalling only (FACCH) channel
                         FAH0 : TCH HR signalling only (FACCH) channel, subch 0
                         FAH1 : TCH HR signalling only (FACCH) channel, subch 1
                         SDCC : SDCCH
                         AGCH : AGCH
                         CCCH : CCCH
                         CBCH : CCCH and cell broadcast receiving on
                         BCCH : BCCH
                         SEAR : SEARCH
                         NSPS : MS is in No Serv Power Save state
             ppp         value of the cell reselection criterium (C2).
                         Range is -99 - 999. If phone is phase 1 then C1 value is
                         shown.
     
     	TXPower
     	5 - 2W (max. GSM900) 	dBm 33
     	6 - 1.3W 		dBm 31
     	7 - 0.8W 		dBm 29
     	8 - 0.5W 		dBm 27
     	9 - 0.32W 		dBm 25
     	10 - 0.2W 		dBm 23
     	15 - 0.02W 		dBm 13


    Test 02 more info of serving cell 

    NET MONITOR
    TEST 02
    
     ++++++++++++++
     + aa b c Bdd +
     + ee f       +
     + ggg hh iii +
     + H=j mm nn  +
     ++++++++++++++
     
             aa      paging mode
                        NO : normal paging
                        EX : extended paging
                        RO : paging reorganization
                        SB : same as before
             b       maximum number of Random Access retransmission
             c       roaming indicator, values are R or empty.
             Bdd     Letter B and BSIC value, range is 0 - 63.
             ee      Reason of last call release
                     Cause from messages disconnect and release complete.
             f       RX quality (full), range is 0 - 7
             ggg     Cell reselect offset, range 0 - 126 dB.
                     0 - 63 * 2 dB. 'xxx' in active mode.
             hh      Temporary offset, range 0 - 60 dB.
                     0 - 7 * 10 dB. 70 dB means infinite time.
                     'xx' in active mode.
             iii     Penalty time, range 0 - 620 s.
                     0 - 31 * 20 s. 'xxx' in active mode.
             j       Hopping channel
                         0    Single RF channel
                         1    RF hopping channel
             mm      mobile allocation index offset, MAIO
                         Range: 00 to 63 / xx when H=0
             nn      hopping sequence number, HSN
                         Range: 00 to 63 / xx when H=0
     
     
     RX Quality (full)
     X - phone is stand-by
     0 - less than 0.2% bit errors
     1 - 0.2 - 0.4% bit errors
     2 - 0.41 - 0.8% bit errors
     3 - 0.81 - 1.6% bit errors
     4 - 1.61 - 3.2% bit errors
     5 - 3.21 - 6.4% bit errors
     6 - 6.41 - 12.8% bit errors
     7 - more than 12.8% bit errors
     


    Test 03 info of serving cell, 1st and 2nd neighbour 

    NET MONITOR
    TEST 03
    
     ++++++++++++++
     +aaabbbcccddd+
     +aaabbbcccddd+
     +aaabbbcccddd+
     +    ef gh   +
     ++++++++++++++
     
             1. row: serving cell information
             2. row: 1. neighbour information
             3. row: 2. neighbour information
             4. row, ef: 1. neighbour information
             4. row, gh: 2. neighbour information
     
             aaa     carrier number in decimal
             bbb     C1 value, range is -99 - 999, displayed only in idle mode.
                     Instead of C1 value, letter 'B' and BSIC value will be
                     displayed in active mode.
             ccc     rx level in dBm, minus sign not shown if <=-100
             ddd     C2 value, range is -99 - 999
             e,g     F is shown if cell is in a forbidden location area
                     otherwise location is empty.
             f,h     B is Barred, N is normal priority and L is low priority
                     otherwise location is empty.
     


    Test 04 info of 3rd, 4th and 5th neighbour 

    NET MONITOR
    TEST 04

     

    ++++++++++++++
     +aaabbbcccddd+
     +aaabbbcccddd+
     +aaabbbcccddd+
     +  ef gh ij  +
     ++++++++++++++
     
             1. row: 3. neighbour information
             2. row: 4. neighbour information
             3. row: 5. neighbour information
             4. row, ef: 3. neighbour information
             4. row, gh: 4. neighbour information
             4. row, ij: 5. neighbour information
     
             aaa     carrier number in decimal
             bbb     C1 value, range is -99 - 999, displayed only in idle mode.
                     Instead of C1 value, letter 'B' and BSIC value will be
                     displayed in active mode.
             ccc     rx level in dBm, minus sign not shown if <=-100
             ddd     C2 value, range is -99 - 999
             e,g,i   F is shown if cell is in a forbidden location area
                     otherwise location is empty.
             f,h,j   B is Barred, N is normal priority and L is low priority
                     otherwise location is empty.


    Test 05 info of 6th, 7th and 8th neighbour 

    NET MONITOR
    TEST 05
    ++++++++++++++
     +aaabbbcccddd+
     +aaabbbcccddd+
     +aaabbbcccddd+
     +  ef gh ij  +
     ++++++++++++++
     
             1. row: 6. neighbour information
             2. row: 7. neighbour information
             3. row: 8. neighbour information
             4. row, ef: 6. neighbour information
             4. row, gh: 7. neighbour information
             4. row, ij: 8. neighbour information
     
             aaa     carrier number in decimal
             bbb     C1 value, range is -99 - 999, displayed only in idle mode.
                     Instead of C1 value, letter 'B' and BSIC value will be
                     displayed in active mode.
             ccc     rx level in dBm, minus sign not shown if <=-100
             ddd     C2 value, range is -99 - 999
             e,g,i   F is shown if cell is in a forbidden location area
                     otherwise location is empty.
             f,h,j   B is Barred, N is normal priority and L is low priority
                     otherwise location is empty.


    Test 06 network selection display 

    NET MONITOR
    TEST 06
    ++++++++++++++
     +aaabb  aaabb+
     +aaabb  aaabb+
     +aaabb  aaabb+
     +aaabb  aaabb+
     ++++++++++++++
     
     1. row: last registered network -  1st forbidden network
     2. row: 1st preferred network   -  2nd forbidden network
     3. row: 2nd preferred network   -  3rd forbidden network
     4. row: 3rd preferred network   -  4th forbidden network
     


    Test 07 information bits for serving cell 

    NET MONITOR
    TEST 07
    ++++++++++++++
     +E A H C I BR+
     +a b c d e fg+
     +ECSC 2Ter MB+
     +  h    i   j+
     ++++++++++++++
     
             a       1 is shown if emergency calls are supported, else 0
             b       1 is shown if attach-detach-procedure is allowed, else 0
             c       1 is shown if half rate channels are supported, else 0
             d       1 is shown if C2 values are broadcasted, else 0
             e       1 is shown if system information 7 and 8 are broadcasted,
                       else 0
             f       1 is shown if cell broadcast is supported, else 0
             g       1 is shown if re-establishment is supported, else 0
     
            The following items are used only in dualband phones:
     
             h       In idle mode 1 is shown if Early Classmark (ECSC) sending is
                     supported, else 0. In dedicated mode (conversation) X is shown.
     
             i       In idle mode 1 is shown if 2-Ter messages are supported,
                     else 0. In dedicated mode (conversation) X is shown.
     
             j       MultiBand reporting decimal value (0,1,2,3) is shown if
                     supported. This is shown both in idle and dedicated mode.
     


    Test 10 values of paging, TMSI, location update 

    NET MONITOR
    TEST 10
    ++++++++++++++
     +TMSIaaaaaaaa+
     +T321:bbb/ccc+
     +PRP:d  ee ff+
     + ggggg  hhh +
     ++++++++++++++
     
             aaaaaaaa    TMSI value in hex format
             bbb         Current value of T3212 counter (range is 000 - 'ccc', where
                         1 means 6 min time.  So, if this value is 2 less than 'ccc'
                         then next periodic location updating will be made within
                         2 * 6 min = 12 minutes.
             ccc         Timeout value of T3212 counter (range is 000 - 240, where 1
                         means 6 min time between location updates and 240 means
                         240 * 6 min = 24 h between location updates. 000 means that
                         periodic location update is not in use.)  This value is
                         received from the network.
             d           Value of paging repeat period (range is 2 - 9, when paging
                         is in every second multiframe, mobile takes more current
                         than if it were in every 9th multiframe)
             ee          Downlink signalling failure value. If value is negative,
                         0 is shown. Maximum value is 45. When mobile is on TCH
                         then xx is shown.
             ff          Gain value on TCH/SDCCH, range is 0 - 93
             ggggg       VCTCXO AFC DAC control, range is -1024 - 1023
             hhh         Serving cell channel number


    Test 11 network parameters 

    NET MONITOR
    TEST 11
    ++++++++++++++
     +CC:aaa NCbbb+
     + LAC:ccccc  +
     + CH : dddd  +
     + CID:eeeee  +
     ++++++++++++++
     
             aaa     MCC value in decimal (MCC=Mobile Country Code)
             bbb     MNC value in decimal (MNC=Mobile Network Code)
                     Three digits are shown only in DCS1900.
                     In other systems only two digits are shown.
             ccccc   LAC value in decimal (LAC=Location Area Code)
             dddd    Serving cell channel number
             eeeee   Cell Identifier in decimal format
     
             LAC and CID may be in hex format in some projects.
             Or even both decimal and hexadecimal formats may be
             shown on the same line.


    Test 12 ciphering, hopping, DTX 

    NET MONITOR
    TEST 12
    ++++++++++++++
     +CIPHER :aaa +
     +HOPPING:bbb +
     +DTX    :ccc +
     +IMSI   :ddd +
     ++++++++++++++
     
             aaa     ciphering value, OFF/A51/A52
             bbb     hopping value, ON/OFF
             ccc     DTX value ON/OFF
             ddd     IMSI attach
                        ON  : IMSI attach on
                        OFF : IMSI attach off
     
         These values are updated only on the TCH.


    Test 13 DTX switching display 

    NET MONITOR
    TEST 13
    With this display it is possible to change MS to use DTX or not, if BS
     allows MS to decide it.
     
     This display must be activated from MENU to change DTX state. When MENU is
     not active and the user is scrolling field test displays with NEXT and
     PREVIOUS, the DTX state will not change.
     
     **************
     *aaaaaaaaaa  *
     *DTX(DEF):bbb*
     *DTX(BS) :ccc*
     *            *
     **************
     
             aaaaaaaaaa  status of switched mode.
                            DTX:ON    : MS uses DTX
                            DTX:OFF   : MS does not use DTX
                            DTX:DEF   : MS use default state of DTX.
                                        Defined in MS_PAR.H
                            NOTALLOWED: BS does not allow MS to decide if it uses
                                        DTX or not.
             bbb         default state of DTX. Defined in MS_PAR.H
                         The value is either ON or OFF
             ccc         is DTX value from BS
                            MAY : BS allows MS to decide if it uses dtx or not
                                  on uplink.
                            USE : BS controls MS to use dtx (on uplink)
                            NOT : BS controls MS not to use dtx (on uplink)
     


    Test 17 BTS TEST 

    NET MONITOR
    TEST 17
            **************                   **************
             *            *                   *            *
             *  BTS TEST  *                   *  BTS TEST  *
             *     ON     *                   *    OFF     *
             *            *                   *            *
             **************                   **************
     
             Mobile is                         Mobile is
             searching only                    behaving normally.
             one frequency.                    Neighbour measurements
             Neighbour measurements            are done.
             are not done.
     
         This display is used to toggle BTS_TEST status on EEPROM. If BTS_TEST
         status is set on EEPROM each time the mobile sends a search list it uses
         only the carrier number stored on SIM SCM-location 33. Also the neighbour
         information from system information messages is ignored. If the BTS_TEST
         status is not set, then the value of SIM SCM-location 33 is ignored and the
         mobile behaves normally (i.e. does the neighbour measurements according the
         GSM specifications).
     
         To activate BTS tests perform following steps:
             - Save desired channel number in SIM SCM-location 33.
             - Select display 17 in execute mode
             - Switch power off and on
         If activation succeeded, there is text "BTS TEST ON" in display 17.
     
         To deactivate BTS tests either select display 17 in execute mode or
         save number 0 in SIM SCM-location 33 and switch power off and on.
     
         NOTE! The display does not show the value of BTS_TEST status in EEPROM.
         Although the value is set, bts test can be off. If there is not legal
         carrier number in SIM location 33 (GSM: 1-124, DCS1800: 512-885) the
         display shows that bts test is off. Also if the mobile was already
         registered to some carrier before switching BTS_TEST status, the display
         can show different value from the one in EEPROM.


    Test 19 toggle cell barred status 

    NET MONITOR
    TEST 19
            **************         **************         **************
             *            *         *            *         *            *
             * CELL BARR  *         * CELL BARR  *         * CELL BARR  *
             * ACCEPTED   *         * REVERSE    *         * DISCARD    *
             *            *         *            *         *            *
             **************         **************         **************
     
         This test is meant to be used when some cells are tested prior taking them
         into commercial use. By setting the barring on in the base station normal
         GSM phones will not try to register these barred cells. By selecting cell
         barring reversed, the MS will only use the cells to be tested. However, if
         at the same time it is wanted that MS will be capable to use normal network
         cell barring ignored can be set. Display 19 will show the cell barring
         mode.
     
         NOTE! If a cell has been selected before barring state is changed the
         selected cell may have different barring state than what the display shows.
         After reselection the cell barring state is working for sure.
     


    Test 20 general information of the charging status 

    NET MONITOR
    TEST 20
    ++++++++++++++
     + aaa  bbbbb +
     + Tccc   ddd +
     + Ceee  Wfff +
     + gggg  hhhh +
     ++++++++++++++
             aaa     Battery voltage in decimal, range is 0.00 - 9.99 V, decimal
                     point is not shown; e.g. 7.19V is shown as 719 on the display
             bbbbb   Charging mode 5 digit symbol
     
                        xxxxx : Charger not connected or charging disabled.
                        Charg : Charging.
                        Maint : Maintenance charging.
                        Faile : Failure.
                        DisCh : Battery discharging going.
                        InitC : EM charging is being initialized.
                        BatCk : Battery testing is going.
                        ChaCk : EM is checking charger.
                        CelBr : Charging off because one or more cells broken
                                inside battery.
                        BSIFa : Charging off because of battery BSI measurement
                                failed.
                        TmpFa : Charging off because of battery NTC measurement
                                failed.
                        VolFa : Charging off because charger voltage measurement
                                failed.
                        CurFa : Charging off because charger current measurement
                                failed.
                        FastC : Fast charging going.
                        FullM : Battery full and maintenance going.
                        HotM  : Battery hot and maintenance going.
                        ColdM : Battery cold and maintenance going.
                        TxOnC : TX on and Ni charging going.
                        TxNoF : TX on, Ni charging going and battery is not
                                full anymore.
                        LithC : Charging of Lithium-ion battery.
                        LiAFu : PWM level is below the battery full limit.
                        LiFul : PWM has been below the battey full limit for
                                a certain time that is  specified for battery
                                full.
                        LiTxO : TX on and Li charging going.
                        LNFTx : TX on, Li charging going and battery is not
                                full anymore.
                        ColdC : Cold charging.
                        I_Che : Init checks.
                        L_Che : Li charging checks.
                        F_Che : Fast charging checks.
                        M_Che : Maintenace charging checks.
                        MaBFD : Maintenace BFD charging.
                        LiDCH : Li-ion DCH charging.
                        LiHot : Li-ion hot charging.
     
             ccc     Battery temperature in centigrade, from -30 to +90.
                     Values for this table can be found from a separate Excel
                     document, stored in 
     NTC_RES.XLS.
             ddd     Charging time. Format is HMM. Timer is automatically
                     reset and started when charger is connected and stopped
                     when battery is full or charger is disconnected.
             eee     Charger voltage in decimal, range is 0.0 - 18.7 V, decimal
                     point is not shown.
             fff     Charge control output, decimal, range is 000 - 255.
             gggg    Lithium battery type (BSI value multiplied by 4),
                     or NiMH battery size.
             hhhh    Battery full delay counter. When battery is getting full and
                     charging current is less than predefined limit, this timer
                     will be started. If timer reaches 0, charging will be stopped.
     


    Test 21 constant voltage charging display 

    NET MONITOR
    TEST 21

     

    ++++++++++++++
     + aaaa  bbbb +
     +  ccc   ddd +
     +  eee   fff +
     +            +
     ++++++++++++++
     
             aaaa    Difference between measured voltage and goal voltage,
                     decimal point is not shown.
             bbbb    Difference between measured voltage and result of previous
                     measurement (basically same as using change of error),
                     decimal point is not shown.
             ccc     Battery up voltage, maximum ripple voltage.
             ddd     Battery down voltage, minimum ripple voltage.
             eee     Average voltage.
             fff     Sum of membership function sets beliefs, range 0.00-9.99,
                     decimal point is not shown; e.g. 1.53 is shown as 153. If sum
                     of 1.00 is reached then battery full indication is given.
     


    Test 22 battery full detection 

    NET MONITOR
    TEST 22

     

    ++++++++++++++
     + Eaaa  Cbbb +
     + Dccc  Rddd +
     + Ieee  Afff +
     + Tggg  Vhhh +
     ++++++++++++++
     
     
             Letters E, C, D, R, I, A, T and V are displayed constantly.
     
             Eaaa    DerivCount membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Cbbb    ChargeAmount membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Dccc    VolDiffToMax membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Rddd    VolDropCnt membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Ieee    VolDiffTime membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Afff    AverDiff membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Tggg    Temperature membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.
     
             Vhhh    Voltage  membership function set, range 0.00-1.00, decimal
                     point is not shown; e.g. 0.23 is shown as 023.


    Test 23 battery monitor and phone state monitor 

    NET MONITOR
    TEST 23

     

    ++++++++++++++
     + aaaa  bbbb +
     + cccc  dddd +
     +eee fff gggg+
     +hhh iiiijjjj+
     ++++++++++++++
     
             aaaa    txon voltage, decimal point not shown (a.aaa mV)
             bbbb    txoff voltage, decimal point not shown (b.bbb mV)
             cccc    charging current, decimal point not shown (c.ccc mA)
             dddd    predicted standby level, decimal point not shown (d.ddd mV)
             eee     estimated age for Li-ion battery (0..100, 0=new, 100=old)
             fff     battery's percentage level (0..100)
             gggg    current consumption indicated by PSM (deci-mA)
             hhh     battery's temperature (C) (Only for Li battery)
             iiii    charged capacity (mAh) (into battery)
             jjjj    tells what is the next capacity target to reach
                     next battery bar level (mAh)
     
     


    Test 35 reasons for SW reset 

    NET MONITOR
    TEST 35

     

    ++++++++++++++
     + aaaaa      +
     + bbbbbbbb   +
     +            +
     +            +
     ++++++++++++++
     
             aaaaa     last reset reason.
                           NORM     : Probably normal power up.
                           UNKNO    : Default value, reset reason is unknown.
                           HW WD    : ASIC watchdog timeout.
                           SWDSP    : DSP recovery reset
                           SWSIM    : SIM contact failure reset
                           SWIDL    : Idle task not running reset
                           STACK    : Task stack overflow
             bbbbbbbb  Name of running task before reset.
     


    Test 36 counters for resets 

    NET MONITOR
    TEST 36

     

    ++++++++++++++
     + aa  bb  cc +
     + dd  ee  ff +
     +            +
     +            +
     ++++++++++++++
     
             aa      Unknown resets.
             bb      ASIC watchdog resets
             cc      DSP recovery resets
             dd      SIM contact failure resets
             ee      Idle task not running resets
             ff      Task stack overflow resets
     
         Counters are stored to EEPROM.
     


    Test 39 info about reasons for call clearing 

    NET MONITOR
    TEST 39

     

    ++++++++++++++
     + CC: aaaa   +
     + MM: bbbb   +
     + RR: cccc   +
     +            +
     ++++++++++++++
     
             aaaa    CC cause value, see section 10.5.4.11/GSM 04.08
                     '*' is shown in front of cause value if cause is made up
                     by CC layer in MS
             bbbb    MM cause value, see section 10.5.3.6/GSM 04.08
                     '*' is shown in front of cause value if cause is made up
                     by MM layer in MS
             cccc    RR cause value, see section 10.5.2.31/GSM 04.08
                     '*' is shown in front of cause value if cause is made up
                     by RR layer in MS
     
             All cause values are shown in decimal form.
     


    Test 40 reset handover counters 

    NET MONITOR
    TEST 40

     

    With this display all timers of the handover display can be reset.
     
     **************
     *   RESET    *
     *  HANDOVER  *
     *  COUNTERS  *
     *            *
     **************
     


    Test 41 singleband handover display 

    NET MONITOR
    TEST 41

     

    ++++++++++++++
     +HandOOK: aaa+
     +PrevCh : bbb+
     +HONotOK: ccc+
     +HOIntra: ddd+
     ++++++++++++++
     
             aaa     counter for successful handovers (max. amount 999)
             bbb     counter for successful back to previous channel attempts
             ccc     counter for failed handovers
             ddd     counter for successful intracell handovers or assignments
                     (max. amount 999)
     
         Counters will stop when they reach their maximum. To initialize the
         counters to zero, select display 40. Also display 60 initializes these
         counters.
     

    Test 43 L2 display 

    NET MONITOR
    TEST 43

     

    ++++++++++++++
     +T200MS :aaaa+
     +T200BS :bbbb+
     +T200MS :cccc+
     +T200BS :dddd+
     ++++++++++++++
     
             aaaa    GSM: Counts how many times T200 in MS has expired and
                          therefore L2 transmission has been repeated.
             bbbb    GSM: Counts how many times T200 in BS (network) has expired
                          and therefore L2 transmission has been repeated.
     
             cccc    DCS: Counts how many times T200 in MS has expired and
                          therefore L2 transmission has been repeated.
                          (for dualband phones)
             dddd    DCS: Counts how many times T200 in BS (network) has expired
                          and therefore L2 transmission has been repeated.
                          (for dualband phones)
     
        Counters will stop when they reach their maximum. To initialize the
        counters to zero, select display 40. Also display 60 initializes these
        counters.
     


    Test 54 block display 1 

    NET MONITOR
    TEST 54

     

    ++++++++++++++
     +aa bb  aa bb+
     +aa bb  aa bb+
     +aa bb  aa bb+
     +aa bb  aa bb+
     ++++++++++++++
     
             1. row: Block set 1, block set 2
             2. row: Block set 3, block set 4
             3. row: Block set 5, block set 6
             4. row: Block set 7, block set 8
     
             aa       Number of reserved blocks
             bb       Number of free blocks in worst case
     


    Test 55 block display 2 

    NET MONITOR
    TEST 55

     

    ++++++++++++++
     +aa bb  aa bb+
     +aa bb  aa bb+
     +aa bb  aa bb+
     +aa bb  aa bb+
     ++++++++++++++
     
             1. row: Block set 9,  block set 10
             2. row: Block set 11, block set 12
             3. row: Block set 13, block set 14
             4. row: Block set 15, block set 16
     
             aaa      Number of reserved blocks
             bbb      Number of free blocks in worst case
     


    Test 56 block display 3 

    NET MONITOR
    TEST 56

     

    ++++++++++++++
     + aaaaaa bbb +
     + cccccccc   +
     +            +
     +            +
     ++++++++++++++
     
             aaaaaa   Pointer to memory where double deallocation was called, in hex
                      format.
             bbb      Counter for failed deallocations.
             cccccccc Name of task which last tried to double deallocate a block.
     
                      Note: This display is only valid when the counter for failed
                      deallocations is not zero.
     


    Test 57 memory status before reset 

    NET MONITOR
    TEST 57

     

    ++++++++++++++
     +aaaaaaaaaaaa+
     +aaaaa...    +
     +bbbbbbbb    +
     +            +
     ++++++++++++++
     
             aaaaaa... Status of each stack before reset. First position contains
                       the status of stack 0, second position the status of
                       stack 1 and so on. The last position contains the status
                       of System stack. Number of stacks depends on the current
                       configuration of SW. Possible values for each stack are:
                           0 : status OK, no overflow
                           1 : status not OK, stack overflow,
             bbbbbbb   Status of each block set before reset. First position
                       contains the status of block set 1, second position the
                       status of block set 2 and so on. Possible values for each
                       block set are:
                           0 : status OK
                           1 : block set full
                           2 : (de)allocation error or total memory corruption
     
                       Note: This display is only valid when a unknown or
                       a stack overflow interrupt has occured.
     


    Test 60 resets field test counters 

    NET MONITOR
    TEST 60

     

    With this display all counters of the field test display can be reset
     (i.e. all counters in 40 and 60 series).
     
     **************
     * FIELD TEST *
     *  DISPLAY   *
     *  COUNTERS  *
     *   RESET    *
     **************
     


    Test 61 search and reselection counters display 

    NET MONITOR
    TEST 61

     

    ++++++++++++++
     +NOPSW  :aaaa+
     +SYNCR  :bbbb+
     +RESELEC:cccc+
     +            +
     ++++++++++++++
     
             aaaa    counter for MDI_NO_PSW_FOUND message received from DSP
                     in hexadecimal form.
             bbbb    counter for synchronization measurement attempts in decimal
                     form. If counter value is over 9999 then four x are shown.
             cccc    counter for cell reselections in hexadecimal form.
     
     
         On poweroff the values of the counter displays are stored onto the EEPROM,
         where they will be read during power on. To initialize the counters to
         zero, select display 60. Counters are automatically reset to zero when
         they exceed their maximum value.
     


    Test 62 neighbour measurment counter display

    NET MONITOR
    TEST 62

     

    ++++++++++++++
     + PSW  :aaaa +
     + SYNCR:bbbb +
     + BCCH :cccc +
     + BCCHE:dddd +
     ++++++++++++++
     
             aaaa    counter for neighbour PSW measurement attempts
             bbbb    counter for neighbour synchronization measurement attempts
             cccc    counter for neighbour BCCH measurement attempts
             dddd    counter for neighbour BCCH Ext measurement attempts
     
             Counter values are shown in hexadecimal form.
     
         On poweroff the values of the counter displays are stored onto the EEPROM,
         where they will be read during power on. To initialize the counters to
         zero, select display 60. Counters are automatically reset to zero when
         they exceed their maximum value.
     

     
    Test 63 call attempts counters 

    NET MONITOR
    TEST 63

     

    ++++++++++++++
     +  aa    bb  +
     +  ccc   ddd +
     +  eee   fff +
     +            +
     ++++++++++++++
     
             aa      Reason of last call release
                     Cause from messages disconnect and release complete
             bb      Direction of last call release
                        UN : Unknown
                        MO : Mobile originated
                        MT : Mobile terminated
                        IN : Internal (ME CS sw)
             ccc     count of all MO call attempts made
             ddd     count of succeeded MO calls
             eee     count of all call setups received
             fff     count of succeeded MT calls
     
     
         On poweroff the values of the counter displays are stored onto the EEPROM,
         where they will be read during power on. To initialize the counters to
         zero, select display 60. Counters are automatically reset to zero when
         they exceed their maximum value.
     


    Test 70 temporary counters of DSP 

    NET MONITOR
    TEST 70

     

    ++++++++++++++
     + aaaa bbbb  +
     + cccc dddd  +
     + eeee ffff  +
     + gggg hhhh  +
     ++++++++++++++
     
             aaaa    Contents of API memory location r_dsp2ftd+0
                     in hex format
             bbbb    Contents of API memory location r_dsp2ftd+1
                     in hex format
             cccc    Contents of API memory location r_dsp2ftd+2
                     in hex format
             dddd    Contents of API memory location r_dsp2ftd+3
                     in hex format
             eeee    Contents of API memory location r_dsp2ftd+4
                     in hex format
             ffff    Contents of API memory location r_dsp2ftd+5
                     in hex format
             gggg    Contents of API memory location r_dsp2ftd+6
                     in hex format
             hhhh    Contents of API memory location r_dsp2ftd+7
                     in hex format
     
             The display is to be used by special debugging DSP SW which can
             put some useful information to the memory locations on API RAM.
             When this display is selected then MCU copies the contents of
             those memory locations into display with format specified above.
     

     


    Test 83 control of task information displays 

    NET MONITOR
    TEST 83

     

    **************
     *            *
     * SHOW TASK  *
     * XXXXXXXXX  *
     *            *
     **************
     
     	XXXXXXXXX is "STACKS", "MSG BUFS" or "FAST BUFS"
     
         Shows what information about tasks is currently shown in displays
         84 - 87.
     
         To select the type of information select this display via menu.
         Type is changed in order STACKS -> MSG BUFS  -> FAST BUFS -> STACKS.
         So, if STACKS is currently displayed and you want to see FAST BUFS,
         you have to select this display twice via menu.
     
         "STACKS"    shows free stack space in worst case.
         "MSG BUFS"  shows the peak number of pending messages.
         "FAST BUFS" shows the peak number of pending fast messages.


    Test 87 information od OS_SYSTEM_STACK

    NET MONITOR
    TEST 87

     

    ++++++++++++++
     + aaaa  bbbb +
     +            +
     +            +
     +            +
     ++++++++++++++
     
         aaaa    OS_SYSTEM_STACK
     
         Values are not stored to EEPROM.
     
    The source taken from: http://mobil.crazy.cz/test.php
     

     
     
     
     
     Tips  Our rules  Car diagnostic  Xprog-T  We are official ressellers
  • Sim Unlock Solutions
  • Nokia Netmonitor
  • Codes for Nokia
  • GSM Network Codes
  • Basic GSM Terms
  • Phone Code Section
  • Phone Pinouts Sect.
  • GSM Technologies
  • Credit Cards Secure
  • Cooperation with Us
  • Contact Information
  • Purchase conditions
  • Delivery Methods
  • Payment Methods
  • Privacy Policy
  • Links; add
  • car diagnostic Xprog-T unlock nokia
     0.0192 s
    Demand on latest news of products updates? Check our mailing list  
    unlock phone
    [c] techgsm.com | techgsm.at | techgsm.be | techgsm.de | techgsm.es | techgsm.gr | techgsm.hu | techgsm.it | techgsm.org.uk | techgsm.pl | techgsm.sk