| Test 01 info of serving cell
NET MONITOR
TEST 01
++++++++++++++
+abbb ccc ddd+
+ e ff g mmmm+
+ nnn ppp+
+ oooo +
++++++++++++++
a H, if carrier numbers are scrolled when hopping is on.
Otherwise ' '.
bbb When mobile is on TCH: DCH carrier number in decimal.
If hopping is on, used channels are scrolled when display is
updated.
ccc rx level in dBm, minus sign not shown if <=-100
ddd tx power level. If transmitter is on, symbol * is shown in
front of the power level value.
e Time Slot, range is 0 - 7
ff Timing advance, range is 0 - 63
g rx quality (sub), range is 0 - 7
mmmm Radio Link Timeout value. If value is negative, 0 is shown.
Maximum value is 64. When mobile is NOT on TCH then xx is shown.
nnn value of the path loss criterium (C1). Range is -99 - 999.
oooo type of current channel
THR0 : TCH HR subchannel 0
THR1 : TCH HR subchannel 1
TFR : TCH FR
TEFR : TCH EFR
F144 : TCH FR data channel, speed 14.4 kbps
F96 : TCH FR data channel, speed 9.6 kbps
F72 : TCH FR data channel, speed 7.2 kbps
F48 : TCH FR data channel, speed 4.8 kbps
F24 : TCH FR data channel, speed 2.4 kbps
H480 : TCH HR data channel, speed 4.8 kbps, subch 0
H481 : TCH HR data channel, speed 4.8 kbps, subch 1
H240 : TCH HR data channel, speed 2.4 kbps, subch 0
H241 : TCH HR data channel, speed 2.4 kbps, subch 1
FA : TCH FR signalling only (FACCH) channel
FAH0 : TCH HR signalling only (FACCH) channel, subch 0
FAH1 : TCH HR signalling only (FACCH) channel, subch 1
SDCC : SDCCH
AGCH : AGCH
CCCH : CCCH
CBCH : CCCH and cell broadcast receiving on
BCCH : BCCH
SEAR : SEARCH
NSPS : MS is in No Serv Power Save state
ppp value of the cell reselection criterium (C2).
Range is -99 - 999. If phone is phase 1 then C1 value is
shown.
TXPower
5 - 2W (max. GSM900) dBm 33
6 - 1.3W dBm 31
7 - 0.8W dBm 29
8 - 0.5W dBm 27
9 - 0.32W dBm 25
10 - 0.2W dBm 23
15 - 0.02W dBm 13
Test 02 more info of serving cell
NET MONITOR
TEST 02
++++++++++++++
+ aa b c Bdd +
+ ee f +
+ ggg hh iii +
+ H=j mm nn +
++++++++++++++
aa paging mode
NO : normal paging
EX : extended paging
RO : paging reorganization
SB : same as before
b maximum number of Random Access retransmission
c roaming indicator, values are R or empty.
Bdd Letter B and BSIC value, range is 0 - 63.
ee Reason of last call release
Cause from messages disconnect and release complete.
f RX quality (full), range is 0 - 7
ggg Cell reselect offset, range 0 - 126 dB.
0 - 63 * 2 dB. 'xxx' in active mode.
hh Temporary offset, range 0 - 60 dB.
0 - 7 * 10 dB. 70 dB means infinite time.
'xx' in active mode.
iii Penalty time, range 0 - 620 s.
0 - 31 * 20 s. 'xxx' in active mode.
j Hopping channel
0 Single RF channel
1 RF hopping channel
mm mobile allocation index offset, MAIO
Range: 00 to 63 / xx when H=0
nn hopping sequence number, HSN
Range: 00 to 63 / xx when H=0
RX Quality (full)
X - phone is stand-by
0 - less than 0.2% bit errors
1 - 0.2 - 0.4% bit errors
2 - 0.41 - 0.8% bit errors
3 - 0.81 - 1.6% bit errors
4 - 1.61 - 3.2% bit errors
5 - 3.21 - 6.4% bit errors
6 - 6.41 - 12.8% bit errors
7 - more than 12.8% bit errors
Test 03 info of serving cell, 1st and 2nd neighbour
NET MONITOR
TEST 03
++++++++++++++
+aaabbbcccddd+
+aaabbbcccddd+
+aaabbbcccddd+
+ ef gh +
++++++++++++++
1. row: serving cell information
2. row: 1. neighbour information
3. row: 2. neighbour information
4. row, ef: 1. neighbour information
4. row, gh: 2. neighbour information
aaa carrier number in decimal
bbb C1 value, range is -99 - 999, displayed only in idle mode.
Instead of C1 value, letter 'B' and BSIC value will be
displayed in active mode.
ccc rx level in dBm, minus sign not shown if <=-100
ddd C2 value, range is -99 - 999
e,g F is shown if cell is in a forbidden location area
otherwise location is empty.
f,h B is Barred, N is normal priority and L is low priority
otherwise location is empty.
Test 04 info of 3rd, 4th and 5th neighbour
NET MONITOR
TEST 04
++++++++++++++
+aaabbbcccddd+
+aaabbbcccddd+
+aaabbbcccddd+
+ ef gh ij +
++++++++++++++
1. row: 3. neighbour information
2. row: 4. neighbour information
3. row: 5. neighbour information
4. row, ef: 3. neighbour information
4. row, gh: 4. neighbour information
4. row, ij: 5. neighbour information
aaa carrier number in decimal
bbb C1 value, range is -99 - 999, displayed only in idle mode.
Instead of C1 value, letter 'B' and BSIC value will be
displayed in active mode.
ccc rx level in dBm, minus sign not shown if <=-100
ddd C2 value, range is -99 - 999
e,g,i F is shown if cell is in a forbidden location area
otherwise location is empty.
f,h,j B is Barred, N is normal priority and L is low priority
otherwise location is empty.
Test 05 info of 6th, 7th and 8th neighbour
NET MONITOR
TEST 05
++++++++++++++
+aaabbbcccddd+
+aaabbbcccddd+
+aaabbbcccddd+
+ ef gh ij +
++++++++++++++
1. row: 6. neighbour information
2. row: 7. neighbour information
3. row: 8. neighbour information
4. row, ef: 6. neighbour information
4. row, gh: 7. neighbour information
4. row, ij: 8. neighbour information
aaa carrier number in decimal
bbb C1 value, range is -99 - 999, displayed only in idle mode.
Instead of C1 value, letter 'B' and BSIC value will be
displayed in active mode.
ccc rx level in dBm, minus sign not shown if <=-100
ddd C2 value, range is -99 - 999
e,g,i F is shown if cell is in a forbidden location area
otherwise location is empty.
f,h,j B is Barred, N is normal priority and L is low priority
otherwise location is empty.
Test 06 network selection display
NET MONITOR
TEST 06
++++++++++++++
+aaabb aaabb+
+aaabb aaabb+
+aaabb aaabb+
+aaabb aaabb+
++++++++++++++
1. row: last registered network - 1st forbidden network
2. row: 1st preferred network - 2nd forbidden network
3. row: 2nd preferred network - 3rd forbidden network
4. row: 3rd preferred network - 4th forbidden network
Test 07 information bits for serving cell
NET MONITOR
TEST 07
++++++++++++++
+E A H C I BR+
+a b c d e fg+
+ECSC 2Ter MB+
+ h i j+
++++++++++++++
a 1 is shown if emergency calls are supported, else 0
b 1 is shown if attach-detach-procedure is allowed, else 0
c 1 is shown if half rate channels are supported, else 0
d 1 is shown if C2 values are broadcasted, else 0
e 1 is shown if system information 7 and 8 are broadcasted,
else 0
f 1 is shown if cell broadcast is supported, else 0
g 1 is shown if re-establishment is supported, else 0
The following items are used only in dualband phones:
h In idle mode 1 is shown if Early Classmark (ECSC) sending is
supported, else 0. In dedicated mode (conversation) X is shown.
i In idle mode 1 is shown if 2-Ter messages are supported,
else 0. In dedicated mode (conversation) X is shown.
j MultiBand reporting decimal value (0,1,2,3) is shown if
supported. This is shown both in idle and dedicated mode.
Test 10 values of paging, TMSI, location update
NET MONITOR
TEST 10
++++++++++++++
+TMSIaaaaaaaa+
+T321:bbb/ccc+
+PRP:d ee ff+
+ ggggg hhh +
++++++++++++++
aaaaaaaa TMSI value in hex format
bbb Current value of T3212 counter (range is 000 - 'ccc', where
1 means 6 min time. So, if this value is 2 less than 'ccc'
then next periodic location updating will be made within
2 * 6 min = 12 minutes.
ccc Timeout value of T3212 counter (range is 000 - 240, where 1
means 6 min time between location updates and 240 means
240 * 6 min = 24 h between location updates. 000 means that
periodic location update is not in use.) This value is
received from the network.
d Value of paging repeat period (range is 2 - 9, when paging
is in every second multiframe, mobile takes more current
than if it were in every 9th multiframe)
ee Downlink signalling failure value. If value is negative,
0 is shown. Maximum value is 45. When mobile is on TCH
then xx is shown.
ff Gain value on TCH/SDCCH, range is 0 - 93
ggggg VCTCXO AFC DAC control, range is -1024 - 1023
hhh Serving cell channel number
Test 11 network parameters
NET MONITOR
TEST 11
++++++++++++++
+CC:aaa NCbbb+
+ LAC:ccccc +
+ CH : dddd +
+ CID:eeeee +
++++++++++++++
aaa MCC value in decimal (MCC=Mobile Country Code)
bbb MNC value in decimal (MNC=Mobile Network Code)
Three digits are shown only in DCS1900.
In other systems only two digits are shown.
ccccc LAC value in decimal (LAC=Location Area Code)
dddd Serving cell channel number
eeeee Cell Identifier in decimal format
LAC and CID may be in hex format in some projects.
Or even both decimal and hexadecimal formats may be
shown on the same line.
Test 12 ciphering, hopping, DTX
NET MONITOR
TEST 12
++++++++++++++
+CIPHER :aaa +
+HOPPING:bbb +
+DTX :ccc +
+IMSI :ddd +
++++++++++++++
aaa ciphering value, OFF/A51/A52
bbb hopping value, ON/OFF
ccc DTX value ON/OFF
ddd IMSI attach
ON : IMSI attach on
OFF : IMSI attach off
These values are updated only on the TCH.
Test 13 DTX switching display
NET MONITOR
TEST 13
With this display it is possible to change MS to use DTX or not, if BS
allows MS to decide it.
This display must be activated from MENU to change DTX state. When MENU is
not active and the user is scrolling field test displays with NEXT and
PREVIOUS, the DTX state will not change.
**************
*aaaaaaaaaa *
*DTX(DEF):bbb*
*DTX(BS) :ccc*
* *
**************
aaaaaaaaaa status of switched mode.
DTX:ON : MS uses DTX
DTX:OFF : MS does not use DTX
DTX:DEF : MS use default state of DTX.
Defined in MS_PAR.H
NOTALLOWED: BS does not allow MS to decide if it uses
DTX or not.
bbb default state of DTX. Defined in MS_PAR.H
The value is either ON or OFF
ccc is DTX value from BS
MAY : BS allows MS to decide if it uses dtx or not
on uplink.
USE : BS controls MS to use dtx (on uplink)
NOT : BS controls MS not to use dtx (on uplink)
Test 17 BTS TEST
NET MONITOR
TEST 17
************** **************
* * * *
* BTS TEST * * BTS TEST *
* ON * * OFF *
* * * *
************** **************
Mobile is Mobile is
searching only behaving normally.
one frequency. Neighbour measurements
Neighbour measurements are done.
are not done.
This display is used to toggle BTS_TEST status on EEPROM. If BTS_TEST
status is set on EEPROM each time the mobile sends a search list it uses
only the carrier number stored on SIM SCM-location 33. Also the neighbour
information from system information messages is ignored. If the BTS_TEST
status is not set, then the value of SIM SCM-location 33 is ignored and the
mobile behaves normally (i.e. does the neighbour measurements according the
GSM specifications).
To activate BTS tests perform following steps:
- Save desired channel number in SIM SCM-location 33.
- Select display 17 in execute mode
- Switch power off and on
If activation succeeded, there is text "BTS TEST ON" in display 17.
To deactivate BTS tests either select display 17 in execute mode or
save number 0 in SIM SCM-location 33 and switch power off and on.
NOTE! The display does not show the value of BTS_TEST status in EEPROM.
Although the value is set, bts test can be off. If there is not legal
carrier number in SIM location 33 (GSM: 1-124, DCS1800: 512-885) the
display shows that bts test is off. Also if the mobile was already
registered to some carrier before switching BTS_TEST status, the display
can show different value from the one in EEPROM.
Test 19 toggle cell barred status
NET MONITOR
TEST 19
************** ************** **************
* * * * * *
* CELL BARR * * CELL BARR * * CELL BARR *
* ACCEPTED * * REVERSE * * DISCARD *
* * * * * *
************** ************** **************
This test is meant to be used when some cells are tested prior taking them
into commercial use. By setting the barring on in the base station normal
GSM phones will not try to register these barred cells. By selecting cell
barring reversed, the MS will only use the cells to be tested. However, if
at the same time it is wanted that MS will be capable to use normal network
cell barring ignored can be set. Display 19 will show the cell barring
mode.
NOTE! If a cell has been selected before barring state is changed the
selected cell may have different barring state than what the display shows.
After reselection the cell barring state is working for sure.
Test 20 general information of the charging status
NET MONITOR
TEST 20
++++++++++++++
+ aaa bbbbb +
+ Tccc ddd +
+ Ceee Wfff +
+ gggg hhhh +
++++++++++++++
aaa Battery voltage in decimal, range is 0.00 - 9.99 V, decimal
point is not shown; e.g. 7.19V is shown as 719 on the display
bbbbb Charging mode 5 digit symbol
xxxxx : Charger not connected or charging disabled.
Charg : Charging.
Maint : Maintenance charging.
Faile : Failure.
DisCh : Battery discharging going.
InitC : EM charging is being initialized.
BatCk : Battery testing is going.
ChaCk : EM is checking charger.
CelBr : Charging off because one or more cells broken
inside battery.
BSIFa : Charging off because of battery BSI measurement
failed.
TmpFa : Charging off because of battery NTC measurement
failed.
VolFa : Charging off because charger voltage measurement
failed.
CurFa : Charging off because charger current measurement
failed.
FastC : Fast charging going.
FullM : Battery full and maintenance going.
HotM : Battery hot and maintenance going.
ColdM : Battery cold and maintenance going.
TxOnC : TX on and Ni charging going.
TxNoF : TX on, Ni charging going and battery is not
full anymore.
LithC : Charging of Lithium-ion battery.
LiAFu : PWM level is below the battery full limit.
LiFul : PWM has been below the battey full limit for
a certain time that is specified for battery
full.
LiTxO : TX on and Li charging going.
LNFTx : TX on, Li charging going and battery is not
full anymore.
ColdC : Cold charging.
I_Che : Init checks.
L_Che : Li charging checks.
F_Che : Fast charging checks.
M_Che : Maintenace charging checks.
MaBFD : Maintenace BFD charging.
LiDCH : Li-ion DCH charging.
LiHot : Li-ion hot charging.
ccc Battery temperature in centigrade, from -30 to +90.
Values for this table can be found from a separate Excel
document, stored in
NTC_RES.XLS.
ddd Charging time. Format is HMM. Timer is automatically
reset and started when charger is connected and stopped
when battery is full or charger is disconnected.
eee Charger voltage in decimal, range is 0.0 - 18.7 V, decimal
point is not shown.
fff Charge control output, decimal, range is 000 - 255.
gggg Lithium battery type (BSI value multiplied by 4),
or NiMH battery size.
hhhh Battery full delay counter. When battery is getting full and
charging current is less than predefined limit, this timer
will be started. If timer reaches 0, charging will be stopped.
Test 21 constant voltage charging display
NET MONITOR
TEST 21
++++++++++++++
+ aaaa bbbb +
+ ccc ddd +
+ eee fff +
+ +
++++++++++++++
aaaa Difference between measured voltage and goal voltage,
decimal point is not shown.
bbbb Difference between measured voltage and result of previous
measurement (basically same as using change of error),
decimal point is not shown.
ccc Battery up voltage, maximum ripple voltage.
ddd Battery down voltage, minimum ripple voltage.
eee Average voltage.
fff Sum of membership function sets beliefs, range 0.00-9.99,
decimal point is not shown; e.g. 1.53 is shown as 153. If sum
of 1.00 is reached then battery full indication is given.
Test 22 battery full detection
NET MONITOR
TEST 22
++++++++++++++
+ Eaaa Cbbb +
+ Dccc Rddd +
+ Ieee Afff +
+ Tggg Vhhh +
++++++++++++++
Letters E, C, D, R, I, A, T and V are displayed constantly.
Eaaa DerivCount membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Cbbb ChargeAmount membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Dccc VolDiffToMax membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Rddd VolDropCnt membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Ieee VolDiffTime membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Afff AverDiff membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Tggg Temperature membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Vhhh Voltage membership function set, range 0.00-1.00, decimal
point is not shown; e.g. 0.23 is shown as 023.
Test 23 battery monitor and phone state monitor
NET MONITOR
TEST 23
++++++++++++++
+ aaaa bbbb +
+ cccc dddd +
+eee fff gggg+
+hhh iiiijjjj+
++++++++++++++
aaaa txon voltage, decimal point not shown (a.aaa mV)
bbbb txoff voltage, decimal point not shown (b.bbb mV)
cccc charging current, decimal point not shown (c.ccc mA)
dddd predicted standby level, decimal point not shown (d.ddd mV)
eee estimated age for Li-ion battery (0..100, 0=new, 100=old)
fff battery's percentage level (0..100)
gggg current consumption indicated by PSM (deci-mA)
hhh battery's temperature (C) (Only for Li battery)
iiii charged capacity (mAh) (into battery)
jjjj tells what is the next capacity target to reach
next battery bar level (mAh)
Test 35 reasons for SW reset
NET MONITOR
TEST 35
++++++++++++++
+ aaaaa +
+ bbbbbbbb +
+ +
+ +
++++++++++++++
aaaaa last reset reason.
NORM : Probably normal power up.
UNKNO : Default value, reset reason is unknown.
HW WD : ASIC watchdog timeout.
SWDSP : DSP recovery reset
SWSIM : SIM contact failure reset
SWIDL : Idle task not running reset
STACK : Task stack overflow
bbbbbbbb Name of running task before reset.
Test 36 counters for resets
NET MONITOR
TEST 36
++++++++++++++
+ aa bb cc +
+ dd ee ff +
+ +
+ +
++++++++++++++
aa Unknown resets.
bb ASIC watchdog resets
cc DSP recovery resets
dd SIM contact failure resets
ee Idle task not running resets
ff Task stack overflow resets
Counters are stored to EEPROM.
Test 39 info about reasons for call clearing
NET MONITOR
TEST 39
++++++++++++++
+ CC: aaaa +
+ MM: bbbb +
+ RR: cccc +
+ +
++++++++++++++
aaaa CC cause value, see section 10.5.4.11/GSM 04.08
'*' is shown in front of cause value if cause is made up
by CC layer in MS
bbbb MM cause value, see section 10.5.3.6/GSM 04.08
'*' is shown in front of cause value if cause is made up
by MM layer in MS
cccc RR cause value, see section 10.5.2.31/GSM 04.08
'*' is shown in front of cause value if cause is made up
by RR layer in MS
All cause values are shown in decimal form.
Test 40 reset handover counters
NET MONITOR
TEST 40
With this display all timers of the handover display can be reset.
**************
* RESET *
* HANDOVER *
* COUNTERS *
* *
**************
Test 41 singleband handover display
NET MONITOR
TEST 41
++++++++++++++
+HandOOK: aaa+
+PrevCh : bbb+
+HONotOK: ccc+
+HOIntra: ddd+
++++++++++++++
aaa counter for successful handovers (max. amount 999)
bbb counter for successful back to previous channel attempts
ccc counter for failed handovers
ddd counter for successful intracell handovers or assignments
(max. amount 999)
Counters will stop when they reach their maximum. To initialize the
counters to zero, select display 40. Also display 60 initializes these
counters.
Test 43 L2 display
NET MONITOR
TEST 43
++++++++++++++
+T200MS :aaaa+
+T200BS :bbbb+
+T200MS :cccc+
+T200BS :dddd+
++++++++++++++
aaaa GSM: Counts how many times T200 in MS has expired and
therefore L2 transmission has been repeated.
bbbb GSM: Counts how many times T200 in BS (network) has expired
and therefore L2 transmission has been repeated.
cccc DCS: Counts how many times T200 in MS has expired and
therefore L2 transmission has been repeated.
(for dualband phones)
dddd DCS: Counts how many times T200 in BS (network) has expired
and therefore L2 transmission has been repeated.
(for dualband phones)
Counters will stop when they reach their maximum. To initialize the
counters to zero, select display 40. Also display 60 initializes these
counters.
Test 54 block display 1
NET MONITOR
TEST 54
++++++++++++++
+aa bb aa bb+
+aa bb aa bb+
+aa bb aa bb+
+aa bb aa bb+
++++++++++++++
1. row: Block set 1, block set 2
2. row: Block set 3, block set 4
3. row: Block set 5, block set 6
4. row: Block set 7, block set 8
aa Number of reserved blocks
bb Number of free blocks in worst case
Test 55 block display 2
NET MONITOR
TEST 55
++++++++++++++
+aa bb aa bb+
+aa bb aa bb+
+aa bb aa bb+
+aa bb aa bb+
++++++++++++++
1. row: Block set 9, block set 10
2. row: Block set 11, block set 12
3. row: Block set 13, block set 14
4. row: Block set 15, block set 16
aaa Number of reserved blocks
bbb Number of free blocks in worst case
Test 56 block display 3
NET MONITOR
TEST 56
++++++++++++++
+ aaaaaa bbb +
+ cccccccc +
+ +
+ +
++++++++++++++
aaaaaa Pointer to memory where double deallocation was called, in hex
format.
bbb Counter for failed deallocations.
cccccccc Name of task which last tried to double deallocate a block.
Note: This display is only valid when the counter for failed
deallocations is not zero.
Test 57 memory status before reset
NET MONITOR
TEST 57
++++++++++++++
+aaaaaaaaaaaa+
+aaaaa... +
+bbbbbbbb +
+ +
++++++++++++++
aaaaaa... Status of each stack before reset. First position contains
the status of stack 0, second position the status of
stack 1 and so on. The last position contains the status
of System stack. Number of stacks depends on the current
configuration of SW. Possible values for each stack are:
0 : status OK, no overflow
1 : status not OK, stack overflow,
bbbbbbb Status of each block set before reset. First position
contains the status of block set 1, second position the
status of block set 2 and so on. Possible values for each
block set are:
0 : status OK
1 : block set full
2 : (de)allocation error or total memory corruption
Note: This display is only valid when a unknown or
a stack overflow interrupt has occured.
Test 60 resets field test counters
NET MONITOR
TEST 60
With this display all counters of the field test display can be reset
(i.e. all counters in 40 and 60 series).
**************
* FIELD TEST *
* DISPLAY *
* COUNTERS *
* RESET *
**************
Test 61 search and reselection counters display
NET MONITOR
TEST 61
++++++++++++++
+NOPSW :aaaa+
+SYNCR :bbbb+
+RESELEC:cccc+
+ +
++++++++++++++
aaaa counter for MDI_NO_PSW_FOUND message received from DSP
in hexadecimal form.
bbbb counter for synchronization measurement attempts in decimal
form. If counter value is over 9999 then four x are shown.
cccc counter for cell reselections in hexadecimal form.
On poweroff the values of the counter displays are stored onto the EEPROM,
where they will be read during power on. To initialize the counters to
zero, select display 60. Counters are automatically reset to zero when
they exceed their maximum value.
Test 62 neighbour measurment counter display
NET MONITOR
TEST 62
++++++++++++++
+ PSW :aaaa +
+ SYNCR:bbbb +
+ BCCH :cccc +
+ BCCHE:dddd +
++++++++++++++
aaaa counter for neighbour PSW measurement attempts
bbbb counter for neighbour synchronization measurement attempts
cccc counter for neighbour BCCH measurement attempts
dddd counter for neighbour BCCH Ext measurement attempts
Counter values are shown in hexadecimal form.
On poweroff the values of the counter displays are stored onto the EEPROM,
where they will be read during power on. To initialize the counters to
zero, select display 60. Counters are automatically reset to zero when
they exceed their maximum value.
Test 63 call attempts counters
NET MONITOR
TEST 63
++++++++++++++
+ aa bb +
+ ccc ddd +
+ eee fff +
+ +
++++++++++++++
aa Reason of last call release
Cause from messages disconnect and release complete
bb Direction of last call release
UN : Unknown
MO : Mobile originated
MT : Mobile terminated
IN : Internal (ME CS sw)
ccc count of all MO call attempts made
ddd count of succeeded MO calls
eee count of all call setups received
fff count of succeeded MT calls
On poweroff the values of the counter displays are stored onto the EEPROM,
where they will be read during power on. To initialize the counters to
zero, select display 60. Counters are automatically reset to zero when
they exceed their maximum value.
Test 70 temporary counters of DSP
NET MONITOR
TEST 70
++++++++++++++
+ aaaa bbbb +
+ cccc dddd +
+ eeee ffff +
+ gggg hhhh +
++++++++++++++
aaaa Contents of API memory location r_dsp2ftd+0
in hex format
bbbb Contents of API memory location r_dsp2ftd+1
in hex format
cccc Contents of API memory location r_dsp2ftd+2
in hex format
dddd Contents of API memory location r_dsp2ftd+3
in hex format
eeee Contents of API memory location r_dsp2ftd+4
in hex format
ffff Contents of API memory location r_dsp2ftd+5
in hex format
gggg Contents of API memory location r_dsp2ftd+6
in hex format
hhhh Contents of API memory location r_dsp2ftd+7
in hex format
The display is to be used by special debugging DSP SW which can
put some useful information to the memory locations on API RAM.
When this display is selected then MCU copies the contents of
those memory locations into display with format specified above.
Test 83 control of task information displays
NET MONITOR
TEST 83
**************
* *
* SHOW TASK *
* XXXXXXXXX *
* *
**************
XXXXXXXXX is "STACKS", "MSG BUFS" or "FAST BUFS"
Shows what information about tasks is currently shown in displays
84 - 87.
To select the type of information select this display via menu.
Type is changed in order STACKS -> MSG BUFS -> FAST BUFS -> STACKS.
So, if STACKS is currently displayed and you want to see FAST BUFS,
you have to select this display twice via menu.
"STACKS" shows free stack space in worst case.
"MSG BUFS" shows the peak number of pending messages.
"FAST BUFS" shows the peak number of pending fast messages.
Test 87 information od OS_SYSTEM_STACK
NET MONITOR
TEST 87
++++++++++++++
+ aaaa bbbb +
+ +
+ +
+ +
++++++++++++++
aaaa OS_SYSTEM_STACK
Values are not stored to EEPROM.
The source taken from: http://mobil.crazy.cz/test.php
|